Electrochemical Sensor Module: Toxic and Harmful Silane Sih4 Industrial High-Precision Gas Concentration Detection Module

Product Details
Customization: Available
Type: Electrochemical Gas Sensor
Conductivity Type: Current
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 8 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Electrochemical Sensor Module: Toxic and Harmful Silane Sih4 Industrial High-Precision Gas Concentration Detection Module
  • Electrochemical Sensor Module: Toxic and Harmful Silane Sih4 Industrial High-Precision Gas Concentration Detection Module
  • Electrochemical Sensor Module: Toxic and Harmful Silane Sih4 Industrial High-Precision Gas Concentration Detection Module
  • Electrochemical Sensor Module: Toxic and Harmful Silane Sih4 Industrial High-Precision Gas Concentration Detection Module
  • Electrochemical Sensor Module: Toxic and Harmful Silane Sih4 Industrial High-Precision Gas Concentration Detection Module
Find Similar Products
  • Overview
  • Product characteristics
  • Product Parameters
  • Applicable scenarios
  • Gas type
Overview

Basic Info.

Model NO.
YF-GK-V3
Output Signal Type
Analog Type
Production Process
SemiConductor Integrated
Material
Plastic
IP Rating
IP68
Sensitivity
High
Customized
Customized
Detection Principle
Electrochemistry
Operating Temperature
-40ºC~80ºC
Working Humidity
0-90% Rh (No Condensation))
Operating Voltage
DC 12-36 V
Signal Output
4-20mA Two-Wire System, RS-485 Output
Transport Package
Carton
Specification
80mm*48mm
Trademark
yifan
Origin
China
HS Code
5302
Production Capacity
10000pieces/Year

Product Description

Electrochemical Sensor Module: Toxic and Harmful Silane Sih4 Industrial High-Precision Gas Concentration Detection ModuleElectrochemical Sensor Module: Toxic and Harmful Silane Sih4 Industrial High-Precision Gas Concentration Detection ModuleElectrochemical Sensor Module: Toxic and Harmful Silane Sih4 Industrial High-Precision Gas Concentration Detection ModuleElectrochemical Sensor Module: Toxic and Harmful Silane Sih4 Industrial High-Precision Gas Concentration Detection ModuleElectrochemical Sensor Module: Toxic and Harmful Silane Sih4 Industrial High-Precision Gas Concentration Detection Module
Module Introduction:
The integrated 4-20mA output product is a toxic gas detection module that integrates sensors and transmission modules. The product design is produced in accordance with national explosion-proof standards. The measuring element adopts advanced imported gas sensors, which have the characteristics of accurate measurement, long service life, high stability, and strong anti-interference ability; This module circuit design has been designed to prevent circuit reverse connection, high voltage, and excessive current, while considering lightning protection in product design.
Product characteristics
Main features of the module:
1. Choose advanced imported electrochemical sensors with long service life;
2. Choose high-precision operational amplifiers and power ICs with stable performance, sensitivity, and reliability;
3. Can accurately detect low or high concentrations of toxic gases;
4. Strong anti-interference ability in product design;
5. Product design includes over range protection, reverse polarity protection, and lightning protection;
6. Product design with low power consumption, standard 4-20mA two-wire signal output;
7. Connection interfaces for module sensors: pump suction, diffusion, flange, flange thread;
8. Working voltage: 8-36VDC;
Product Parameters
Module model: YF-GK-V3
Gas detection: Toxic gases (CO H2S SO2 CH2O H2O2, etc.)
Detection principle Principles of electrochemistry
Sampling method Diffuse pump suction flange type, flange thread type
response time 30 S to 40 S (sensor response speed)
Module detection accuracy ≤± 3% FS (actual concentration, higher accuracy depends on specific sensor)
Module repeatability ≤±2%
Modular line error ≤±2%
Module zero drift ≤± 2% (F.S/year)
Module operating temperature -40~80ºC
Module environment humidity 0-95% RH (no condensation)
Sensor operating temperature -20ºC-50ºC
Sensor working humidity 0-90% RH (no condensation)
signal output 4-20mA two-wire system, RS-485 output
transmission distance 100 meters
working voltage DC 12-36 V
maximum power ≤0.8W
Product size 80*48mm
Explosion proof grade Intrinsic safety type
Connecting cables RVVP3×1.5mm2
Applicable scenarios

Module application field
Petroleum, petrochemical, metallurgical, chemical, power, telecommunications, gas, mining, pharmaceuticals, municipal sewage treatment, indoor environment, atmospheric environmental protection, transportation equipment, transportation, tunnel safety, underground parking lots.
 

Gas type

Table 1: Comparison Table of Measurement Type Number and Name (Gas Part, Customization for Other Gases)

Serial number Chemical formula Serial number Chemical formula
01 CO 12 F2
02 H2S 13 HF
03 O2 14 HCL
04 NO2 15 HBr
05 SO2 16 COCl2
06 Cl2 17 SiH4
07 NH3 18 ClO2
08 H2 19 BR2
09 PH3    
10 CH2O    
11 O3    

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier